OUR CAPABILITY
Our dedicated and environmentally controlled RF Standards Room offers ability to measure and generate signals of up to 26 GHz, enabling us to repair and calibrate a full range of RF & Microwave Test Equipment including Spectrum Analysers, Power Meters, and Attenuators.
General Capabilities
Frequency/Time: Measure: Up to 5 GHz, Generate: Up to 26 GHz
The Time & Frequency Laboratory maintains time and frequency standards derived from our GPS Frequency Reference to provide calibration services for a variety of your time and frequency test and test and measurement equipment (T&ME).
This includes Counters, Generators, Tachometers, Process Calibrators, Time Bases, Oscillators, and various other time and frequency-related T&ME.
General Capabilities
Frequency/Time: Measure: Up to 5 GHz, Generate: Up to 26 GHz
CALIBRATION OF INSTRUMENTS
|
|
DC/LF
The DC/LF Laboratory maintains a variety of electrical reference standards, multifunction calibrators, precision multimeters and various other calibration standards to provide calibration services for a variety of electrical test and measuring equipment (T&ME).
Calibration parameters include voltage, current, resistance, time and frequency, distortion, capacitance, and other related electrical parameters.
This includes Multimeters, Signal Sources, Function Generators, Counters, Process Calibrations, Clamp Meters, Insulation Testers, Data Acquisition Systems, LCR meters, Recorders, and various other electrical T&ME.
CALIBRATION CAPABILITY TABLE
Scope |
Electrical |
|||||||||||
Parameter |
DC Voltage |
AC Voltage |
DC Current |
AC Current |
Resistance |
Capacitance |
||||||
Unit |
Volts |
Volts |
Amps |
Amps |
Ohm |
Farads |
||||||
Symbol |
V |
V |
A |
A |
Ω |
F |
||||||
Source/Generate |
0 V |
0 |
0 |
0 |
1 mΩ |
1 pF |
||||||
1000 V |
1000 V |
20 A |
50 A |
1 TΩ |
110 mF |
|||||||
Measure |
100 mV |
1 mV |
1 pA |
5 µA |
0 Ω |
1 pF |
||||||
100 mV |
1000 V |
100 A |
100 A |
200 TΩ |
1 mF |
Scope |
Electrical |
|||||||||||
Parameter |
Inductance |
Power/ |
DC high Voltage |
AC High Voltage |
Speed (Non-Contact) |
Time |
||||||
Unit |
Henri |
Watts |
Volts |
Volts |
rpm |
Hours |
||||||
Symbol |
H |
W |
V |
V |
rpm |
hr |
||||||
Source/Generate |
100 µH |
0.1 W |
|
|
60 rpm |
|
||||||
10 H |
20 kW |
Up to ± 10kV |
Up to 10kV |
99999 rpm |
|
|||||||
Measure |
1 ΩH |
|
|
|
10 rpm |
|
||||||
10 H |
Up to 18 kW |
Up to ±40 kV |
Up to 40 kV |
99999 rpm |
Up to 24 hrs |
Scope |
Acoustic & Vibration |
|
Parameter |
Sound Calibrator |
Sound Level Meter |
Unit |
Decibel |
Decibel |
Symbol |
dB |
dB |
Range |
94 dB to 124 dB |
94 dB to 134 dB |
CALIBRATION OF INSTRUMENTS
|
|